INSTR ¼” SONY SUPER HAD CCD COLOR DAY & NIGHT MINITRAX DOME CAMERA ART. 40797 Please read this manual thoroughly before use and keep i

Strany 2

4 2.2 Base Installation 1. Make mounting holes and cable hole in the place (ceiling) to wich this dome camera is installed using the suppl

Strany 3

5 AC+ AC R+ R G AI G AO 2.3 Basic Configuration PTZ Dome Camera System CAUTION Do not connect the power cable until all other conn

Strany 4 - Important Safeguards

6 2.4 Setting Dome Camera Termination The device which is connected at end of line, whether it be a dome camera or keyboard controller, mu

Strany 5

7 2.5 Setting the Protocol of Dome Camera Dip Switch2 Dip Switch1 Dome ID Setting Dome Camera Function Dome Camera Protocol Functi

Strany 6

8 O N 1 2 3 4 5 6 7 8 9 0 2.6 Setting Address (ID) of Dome Camera To prevent wrong operation and malfunction, each dome camera must have a uniq

Strany 7 - 1.1 Features

9 27 ON ON OFF ON ON OFF 28 OFF OFF ON ON ON OFF 29 ON OFF ON ON ON OFF 30 OFF ON ON ON ON OFF 31 ON ON ON ON ON OFF

Strany 8

10 1 2 3 4 5 6 7 8 9 0 O N 1 2 3 4 5 6 7 8 9 0 O N 1 O 2 N 3 4 5 6 7 8 9 0 For example : ID Address SW1 SW2 SW3

Strany 9 - Accessory connector

11 2.7 Connecting Wiring 2.7-1 Connecting to the RS-485 The dome camera can be controlled remotely by an external device or control system, suc

Strany 10

12 3 Program and Operation Notice The symbols shown below mean some action of the joystick controller is required. / : move joystick up and do

Strany 11 - CAUTION

13 3.3 Preset Menu PRESET MENU NUMBER: 01 TITLE: ========== 0/1234567890 1/1234567890 * * * 2/1234567890 3/1234567890 4/1234567890

Strany 12

WARNINGS AND CAUTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY

Strany 13

14 You can select the Home Position from the saved presets. 3.3-2 Set ShortCut Preset 1. First of all move the dome to the desired position usi

Strany 14

15 3.4 Tour Menu TOUR MENU TOUR : 1 TITLE: ========== DWELL TIME: 10 SEC SPEED: 07 == == == == == == == == == == == == == == == == SAVE EXIT

Strany 15

16 3.5 Auto Scan Menu AUTO SCAN MENU SCAN: 1 TITLE: ========== START POINT: 000.0 000.0 END POINT: 000.0 000.0 SCAN DIR. : CW SPEED: 07 SWAP:

Strany 16 - For example :

17 9. SWAP will change the PAN position between START POINT and END POINT. 10. Select SAVE to save this Auto Scan. 11. Select EXIT to escape thi

Strany 17 - 2.7 Connecting Wiring

18 3.6 Area Title Menu AREA TITLE MENU AREA: 1 TITLE: AREA1====== START POINT: 000.0 END POINT: 045.0 SAVE EXIT / : move cursor up and d

Strany 18

19 3.7 Alarm Menu ALARM MENU INPUT: NC OUTPUT: NO OPTION: TIME OUT PRESET: 01 HOLDING TIME: 10 SEC SAVE AND EXIT EXIT / : move cursor up and

Strany 19 - 3.3 Preset Menu

20 3.8 Camera Setup Menu CAMERA SETUP MENU FOCUS CONTROL WB CONTROL AE CONTROL L/L CONTROL PICTURE NIGHT SHOT CONTROL INITIALIZE CAMERA EXI

Strany 20 - 3.3-4 Home Position

21 3.8 Camera Setup Menu, continued 3.8-1 Focus Control Menu FOCUS CONTROL MENU MODE: AUTO DISTANCE: 0.1M DIGITAL ZOOM: OFF SAVE AND EXIT E

Strany 21 - 3.4 Tour Menu

22 3.8 Camera Setup Menu, continued 3.8-2 WB Control Menu WB CONTROL MENU MODE: AWB RGAIN: BGAIN: SAVE AND EXIT EXIT / : move cursor up

Strany 22 - 3.5 Auto Scan Menu

23 3.8 Camera Setup Menu, continued 3.8-3 AE Control Menu AE CONTROL MENU MODE: AUTO SHOT: NORMAL SHUTTER: IRIS: GAIN: BRIGHT: 30 BLC MODE:

Strany 23 - 3.5-4 Recall Auto Scan

ISSUE 1 - JULY 2007 LIMITATION OF LIABILITY THE INFORMATION IN THIS PUBLICATION IS BELIEVED TO BE ACCURATE IN ALL RESPEC

Strany 24 - 3.6 Area Title Menu

24 BRIGHT: 0 ~ 90 The brightness value is changeable from 0 to 90. BLC MODE: ON / OFF The Back Light Compensation is active when ON is set. BL

Strany 25 - 3.7 Alarm Menu

25 3.8 Camera Setup Menu, continued 3.8-4 L/L Control Menu L/L CONTROL MENU SYNC: INTERNAL PHASE: SAVE AND EXIT EXIT / : move cursor up

Strany 26 - 3.8 Camera Setup Menu

26 3.8 Camera Setup Menu, continued 3.8-5 Picture Menu PICTURE MENU SHARPNESS: 08 MIRROR: OFF FREEZE: OFF NEGA/POSI: POSI DNR: ON PIP: OFF

Strany 27 - 3.8-1 Focus Control Menu

27 3.8 Camera Setup Menu, continued 3.8-6 Night Shot Control Menu NIGHT SHOT CONTROL MENU D/N MODE: AUTO D/N LEVEL: HIGH DELAY: 10 SEC SAVE

Strany 28 - 3.8-2 WB Control Menu

28 3.8 Camera Setup Menu, continued 3.8-7 Initialize Camera If you run this menu, camera's all setting options are initialized as defaul

Strany 29 - 3.8-3 AE Control Menu

29 3.9 Dome Setup Menu DOME SETUP MENU TILT AUTO FLIP: ON 485-TERMINATION: OFF ACKNOWLEDGE: ON AUTO CALIBRATION PASSWORD OSD DISPLAY HOME FU

Strany 30

30 3.9 Dome Setup Menu, continued 3.9-4 Auto Calibration Menu AUTO CALIBRATION MENU EXECUTION EXIT / : move cursor up and down. : select

Strany 31 - 3.8-4 L/L Control Menu

31 3.9 Dome Setup Menu, continued 3.9-5 Password Menu PASSWORD MENU DISPLAY: OFF CHANGE PASSWORD: ==== SAVE AND EXIT EXIT / : move curso

Strany 32 - 3.8-5 Picture Menu

32 3.9 Dome Setup Menu, continued 3.9-6 OSD Display Menu OSD DISPLAY MENU DOME ID: ON PT POSITION: ON PAN DIRECTION: OFF TOUR ELEMENT: OF

Strany 33

33 3.9 Dome Setup Menu, continued 3.9-7 Home Function Menu HOME FUNCTION MENU MODE: ON FUNCTION TYPE: PRESET FUNCTION NUMBER: 01 DWELL TIME

Strany 34 - 3.8-7 Initialize Camera

Important Safeguards 1. Read Instructions All the safety and operating instructions should be read before the appliance is operated. 2. Retain Inst

Strany 35 - 3.9 Dome Setup Menu

34 3.9 Dome Setup Menu, continued 3.9-8 Initialize Dome INITIALIZE DOME MENU PRESET DATA TOUR DATA AUTO SCAN DATA AREA TITLE DATA DOME SETU

Strany 36 - 3.9-4 Auto Calibration Menu

35 4 Troubleshooting and Maintenance 4.1 Troubleshooting If you experience difficulties operating your camera, refer to the following. If

Strany 37 - 3.9-5 Password Menu

36 4.2 Preventive Maintenance Following the preventive maintenance schedule allows detection and correction of minor faults before they becom

Strany 38 - 3.9-6 OSD Display Menu

37 5 Specifications 5.1 General Specifications MODEL NTSC PAL Power Source DC12V / AC24V ±10% POWER Power Consumption 12.0 Watts Image S

Strany 39 - 3.9-7 Home Function Menu

38 5.1 General Specifications, continued MODEL NTSC PAL Panning Angle 360°continuous rotation Panning Speed Manual : Max. 150°/sec. Auto : M

Strany 40 - 3.9-9 Dome Information

39 5.2 Dimensions TOP VIEW SIDE VIEW BOTTOM VIEW

Strany 41 - 4.1 Troubleshooting

40 APPENDIX. PELCO PROTOCOL FUNCTION LIST FUNCTION KEY Preset No. How To. EXAMPLE PRESET PRESET 1 - 60 No.+PRESET 1+PRESET PRESET shortcut sa

Strany 43

Via Don Arrigoni, 5 24020 Rovetta S. Lorenzo (Bergamo) http://www.comelit.it – E mail: [email protected]

Strany 44

12. Servicing Do not attempt to service this equipment yourself. Refer all servicing to qualified service personnel. 13. Damage requiring Service U

Strany 45

FCC COMPLIANCE STATEMENT. FCC INFORMATIONS: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR CLASS A DIGITAL DEVICE

Strany 46

1 1 Introduction 1.1 Features The PTZ Dome keyboard controller and the PTZ Dome camera make up the building blocks for any surveillance/securi

Strany 47

2 1.2 Operation Requirements ALARM INPUT SENSOR ALARM OUTPUT SIREN RS-485 FLASHING LIGHT MULTIPLEXER J-BOX VIDEO CAMERA.1 C

Strany 48 - 50302171

3 G AI G AO AC+ AC R+ R 2 Installation and Connection 2.1 Package Contents Dome camera Instruction manual (This documen